Contact block identification dataExample: RAFIX 22 QR 1.20.124.xxx/5.00.100.1xx
Rated values to IEC 61058-1 10/100(6)[3,6] 250 ~ 7.5 (4) 400 ~ 5E4 25T70
Explanation of data from left to right, current-related data first
10 or 7.5 10A ohmic load at 250V, 7.5 A ohmic load at 400 V
100 100A capacitive peak input current (tested at 250V) (descending E-function to rated current)
(6) or (4) 6A motor rated current at 250V, 4A motor rated current. The test specimen makes 6 times the motor rated current, 36A or 24A, cos phi = 0.6, ^= 9000 or 9600 VA at 400 V throughout the full durability test.
[3,6] 3.6A filament lamp rated current = 36A peak input current (tested at 250V)
250 AC or 400 AC Rated voltages and mains type, ~ = AC
5E4 50,000 operations (no. of test cycles) ^= 5 x 104
25T70 -25°C lower operating temperature and + 70°C upper operating temperature. The first 25,000 operations were tested at +70°C, the remaining 25,000 operations at -25°C in all of the tests.
CURus ratings A 600, 10A/250Vac
A 600 Thermal continuous test current 10A Max. permitted load in VA: Max. 7,200VA make, 720VA break Max. make values: | Max. break values: | 60A/120V | 6A/120V | 30A/240V | 3A/240V | 15A/480V | 1.5A/480V | 12A/600V | 1.2A/600V |
10A/250Vac Ohmic AC load
Rated values to IEC 60947-5-1 U 400 V AC12 10A, AC 15 6A/250V DC13 Q 300
U 400V Rated insulation voltage for use in devices designed for continuous duty and degree of contamination 3
AC12 10A 10A ohmic load and semiconductor load
AC15 6A/250V Controlling electromagnetic loads Max. 60A cos phi = 0.3 at 250V AC make, 6A cos phi = 0.3 at 250V AC break
DC13 Q 300 Controlling solenoids (DC) Maximum thermal continuous current 2.5A Max. 0.55A at 120V – make and break Max. 0.27A at 250V – make and break |